top of page
Search

ZUMI Manipulator: Specs, SKUs, and How to Order in the US


Specialist inspecting packaged ZUMI uterine manipulator

The ZUMI (Zinnanti Uterine Manipulator-Injector), manufactured by CooperSurgical, is a single-use, sterile uterine manipulator built from clear PVC that combines manipulation and injection in one device. If you need to place an order today, the canonical SKU for the 4.5 mm model is ZSI1151, packaged in multiple units per box. Procurement channels in the United States include the CooperSurgical product page, major surgical distributors such as McKesson, and Queenssurgical as an online procurement option.

 

One critical note before you search: the name “Zumi” also belongs to an educational robotics kit sold by Robolink. Always include the full device name “Zinnanti Uterine Manipulator-Injector” and the catalog code (ZSI1151 or the appropriate ZSI#### variant) on every purchase order to prevent a nonmedical shipment from landing in your supply room.

 

  • Device: ZUMI (Zinnanti Uterine Manipulator-Injector)

  • Manufacturer: CooperSurgical

  • Material: Clear PVC, single-use, sterile

  • Function: Combined uterine manipulation and injection

  • Key SKU example: ZSI1151 (ZUMI 4.5 mm, 12/box)

  • US procurement: CooperSurgical direct, McKesson, Queenssurgical

 

Table of Contents

 

 

What are the ZUMI model variants and full specifications?

 

The ZUMI family covers three diameter options, each assigned a distinct manufacturer order code. Diameter is not interchangeable across cases, so procurement and clinical teams need to track each model separately in inventory.

 

Model

Diameter

SKU / Order Code

Pack Size

Typical Use Context

ZUMI 4.5

4.5 mm

ZSI1151

12/box

Standard diagnostic laparoscopy, fertility exams

ZUMI 4.0

4.0 mm

ZSI1152

12/box

Intermediate anatomy, moderate manipulation range

ZUMI 2.0

2.0 mm

ZSI1153

12/box

Smaller-diameter access, minilaparotomy applications


Infographic comparing ZUMI model sizes and SKUs

All three models are single-use and sterile, constructed from clear PVC, and meet USP recommendations for implant testing. The clear material gives the clinician visual confirmation of fluid flow during injection. Packaging across the line is in multiple units per box, which is the standard unit for distributor catalog listings and purchase orders.

 

Diameter selection directly affects passage ease and the range of uterine manipulation achievable intraoperatively. The 4.5 mm model is the most commonly stocked because it suits the widest range of standard laparoscopic cases. Smaller diameters are not a substitute for the 4.5 mm in cases requiring full manipulative range; they serve anatomically distinct indications.

 

Pro Tip: Stock each diameter under its own SKU line in your inventory system. Lumping ZSI1151, ZSI1152, and ZSI1153 under a single “ZUMI” entry is the fastest way to run short on the size your OR actually needs.

 

What are the clinical indications and key IFU points for the ZUMI?

 

The manufacturer IFU lists four primary indications:

 

  1. Diagnostic laparoscopy

  2. Minilaparotomy

  3. Fertility examinations

  4. Salpingoplastic procedures

 

These are the only indications CooperSurgical has validated. Using the device outside these indications is outside the scope of the IFU, and clinicians should review the full IFU PDF before first use or when onboarding new OR staff.

 

Contraindications and sterility handling

 

The IFU specifies contraindications and sterile handling requirements that procurement teams should confirm are communicated to clinical staff at point of receipt. Packaging must arrive sealed and intact; any compromised seal is grounds for rejection and return. Lot numbers and expiration dates printed on the outer packaging are the traceability anchors for recall responsiveness.

 

The ZUMI IFU requires clinicians to follow specific insertion and manipulation steps tied to each model diameter. Deviating from the IFU-specified technique increases the risk of uterine trauma and can compromise injector function. Always consult the full IFU PDF before clinical use.

 

Combined manipulation and injection: the workflow benefit

 

One design feature worth flagging for clinical teams: the ZUMI combines manipulation and injection in a single instrument, which can reduce the need for a separate tenaculum in many cases. Fewer instruments on the field means fewer handoffs and a shorter setup sequence. That said, the IFU is explicit about insertion technique, and clinicians should not assume the injector function eliminates all secondary instrumentation in every case.

 

Pro Tip: Download the IFU PDF directly from the CooperSurgical product page and store it in your facility’s document management system. When a new lot arrives, cross-check the IFU version number on the packaging against the version on file.

 

How do you order ZUMI devices in the United States?

 

Ordering the correct device comes down to three things: the right SKU, the right supplier channel, and a receiving checklist that catches errors before a device reaches the OR.

 

Supplier channels

 

  1. CooperSurgical direct — The manufacturer product page lists all three SKUs and links to the IFU. Direct ordering is the most reliable route for IFU version confirmation and lot traceability documentation.

  2. McKesson — McKesson’s catalog lists the ZUMI under SKU ZSI1151 with per-box pricing and stock availability notes. Institutional accounts can often negotiate contract pricing.

  3. Queenssurgical — An online procurement option for US healthcare facilities, offering both individual and bulk ordering. Useful when distributor lead times are extended or when consolidating multiple supply categories in one order.

  4. Other surgical distributors — Additional catalog listings appear across US surgical supply distributors. Always verify the SKU against the manufacturer code before confirming an order.

 

Pricing expectations

 

Per-box pricing is the standard unit for catalog listings. Institutional and contract orders typically require a formal quote request rather than a published list price. Expect pricing to vary by volume tier and account type. For large-quantity purchases, request a formal quote from your distributor account representative rather than relying on a catalog price.

 

Ordering Detail

What to Confirm

SKU on PO

ZSI1151 (4.5 mm), ZSI1152 (4.0 mm), ZSI1153 (2.0 mm)

Pack size

multiple units per box

Pricing basis

Per box; bulk/contract pricing via quote

Lead time

Confirm with supplier at time of order

Return policy

Some distributors mark sterile single-use items non-returnable

IFU version

Confirm version matches facility’s document on file

Procurement checklist

 

  1. Confirm the exact SKU and diameter match your clinical requirement.

  2. Include the full device name “Zinnanti Uterine Manipulator-Injector” on the PO to prevent confusion with the Robolink robotics product.

  3. Request lot number and expiration date documentation from the supplier.

  4. Verify sterility seal integrity on receipt before accepting the shipment.

  5. Confirm lead time and return/replacement policy in writing before placing a large-volume order.

  6. File the current IFU PDF in your facility’s document management system at the time of first receipt.

 

For a broader look at how to vet surgical supply vendors before committing to volume orders, the vendor comparison checklist from Queenssurgical covers lead time, return policy, and lot traceability criteria in detail.

 

How do you choose the right ZUMI size for your caseload?

 

Diameter selection is a clinical decision, not a procurement default. The 4.5 mm model (ZSI1151) is the standard starting point for most diagnostic laparoscopy and fertility examination cases. It provides the broadest manipulation range and is the most widely stocked across US distributor catalogs.

 

The 4.0 mm model (ZSI1152) fits cases where anatomy or patient factors call for a slightly smaller instrument but full manipulation capability is still required. The 2.0 mm (ZSI1153) is the narrowest option, suited to minilaparotomy and cases where cervical access is restricted.

 

Selecting the wrong diameter is not just a clinical risk — it creates inventory waste. A 4.5 mm device cannot substitute for a 2.0 mm in a restricted-access case, and a 2.0 mm will not deliver the manipulation range needed for standard diagnostic laparoscopy. Match the order to the procedure list, not to what is already on the shelf.

 

Compatibility considerations

 

Before ordering, confirm that your laparoscopic system’s working channel dimensions are compatible with the selected ZUMI diameter. Check instrument clearance for colpotomy accessories if those are part of your standard setup. The IFU specifies the insertion technique for each diameter; compatibility with ancillary equipment should be verified against those specifications, not assumed.


Surgeon's gloved hands checking ZUMI device compatibility

Pro Tip: Before placing a large-volume order of any single diameter, have the lead clinician or OR manager sign off on a trial of at least one box. A single-box trial is far less expensive than returning a non-returnable pallet of the wrong size.

 

For practical guidance on sourcing surgical supplies efficiently and reducing ordering errors, Queenssurgical’s procurement guide covers vendor evaluation and PO best practices.

 

Preparation, handling, and clinical tips for safe use

 

Receiving and storage

 

Inspect every box on arrival. Confirm the outer packaging is sealed, the lot number and expiration date are legible, and the sterility indicator is intact. Store per the IFU’s environmental requirements — temperature and humidity conditions specified in the IFU are not suggestions. A device stored outside those parameters is a device whose sterility cannot be guaranteed.

 

  • Check lot number against your facility’s receiving log at the time of delivery.

  • Reject any unit with a compromised seal or illegible labeling.

  • Store in original packaging until point of use.

  • Do not stack heavy items on top of boxed ZUMI units; packaging damage can compromise the sterile barrier.

 

Setup and insertion

 

The ZUMI’s combined manipulation and injection design can reduce the need for a secondary tenaculum in many procedures, which shortens setup time and reduces instrument count on the sterile field. Follow the IFU-specified insertion sequence for the diameter in use. The technique differs by model, and applying the 4.5 mm insertion steps to a 2.0 mm device is a common source of handling errors.

 

Injection technique and backflow prevention

 

When using the injection function, confirm the injector is fully seated before initiating flow. Partial seating is the most common cause of backflow or misplaced injection. After injection, withdraw per the IFU sequence rather than removing the device abruptly.

 

Pro Tip: Brief the scrub tech on the IFU insertion sequence before the first case with a new lot or a new diameter. A 60-second verbal walkthrough at setup prevents the majority of intraoperative handling errors.

 

Intraoperative checks

 

  • Confirm the device is seated and stable before beginning manipulation.

  • If resistance is encountered during insertion, do not force advancement. Withdraw and reassess per IFU guidance.

  • Single-use designation means one device per procedure. Do not reprocess or reuse.

 

What regulatory and safety requirements apply to US purchasers?

 

The ZUMI is a single-use sterile medical device. In the US, single-use designation carries a clear regulatory implication: reprocessing or reuse is prohibited. The manufacturer’s IFU and the CooperSurgical product page are the authoritative references for safety, usage, and lot traceability requirements.

 

Sterility and lot traceability

 

Confirming IFU version and lot traceability at receipt is the standard practice for single-use sterile devices. It closes the compliance gap between ordering and use, and it is the mechanism that makes recall responsiveness possible. A facility that cannot produce lot numbers for devices used in a specific procedure window cannot respond to a manufacturer recall effectively.

 

The ZUMI meets USP recommendations for implant testing, which is a material-level safety standard. That designation is relevant when your facility’s value analysis committee reviews the device or when biocompatibility documentation is required for credentialing purposes.

 

Returns and distributor policies

 

Some US distributor listings for sterile single-use devices note non-returnable status. This is standard practice for sterile consumables, not a ZUMI-specific restriction. Confirm the return and replacement policy with your distributor before placing any order, particularly for large-volume purchases. Processing times and restocking policies vary by distributor and account type.

 

This article provides general procurement and clinical reference information. Confirm current regulatory requirements, IFU specifications, and distributor policies with CooperSurgical or a qualified clinical specialist before use.

 

Key Takeaways

 

The ZUMI (Zinnanti Uterine Manipulator-Injector) by CooperSurgical is a single-use, sterile, clear PVC device available in three diameters (4.5 mm, 4.0 mm, 2.0 mm), each with a distinct SKU, and procurement accuracy depends on using the correct catalog code on every purchase order.

 

Point

Details

Confirm SKU and diameter

ZSI1151 = ZUMI 4.5 mm, ZSI1152 = 4.0 mm, ZSI1153 = 2.0 mm, all 12/box.

Verify IFU and lot traceability

Check IFU version, lot number, and sterility seal on every shipment received.

Use the full device name on POs

“Zinnanti Uterine Manipulator-Injector” prevents confusion with the unrelated Robolink robotics product.

Match diameter to procedure

Diameters are not interchangeable; get clinician sign-off before large-volume orders.

Queenssurgical as a procurement option

Queenssurgical offers online ordering for ZUMI devices across the US, with both individual and bulk purchasing available.

Why Queenssurgical lists the ZUMI and how we support buyers

 

Queenssurgical carries the ZUMI because procurement errors on single-use sterile devices are expensive and preventable. The most common mistake we see is an order placed under a generic product name without a SKU, which is how a facility ends up with the wrong diameter or, in the case of “Zumi,” an entirely wrong product category. Our catalog listings use manufacturer SKU codes as the primary identifier, and we make IFU access part of the product record so clinical teams can pull the document without a separate search.

 

For first-time orders or facilities switching distributors, our sales team can walk through SKU verification, lot traceability documentation, and lead time expectations before a PO is submitted. That step takes minutes and eliminates the most common receiving errors. Contact Queenssurgical directly to request a quote or confirm availability for your facility’s ZUMI requirement.

 

Order ZUMI devices through Queenssurgical

 

Queenssurgical gives US healthcare facilities a direct online path to order surgical consumables without the back-and-forth of traditional distributor negotiations. For ZUMI devices specifically, that means verified SKUs, clear pack-size information, and a procurement team that knows the difference between ZSI1151 and a robotics kit.


Queenssurgical

Whether you need a single box for a trial or a standing bulk order for a high-volume gynecology service, Queenssurgical handles both. Browse the disposable medical face masks and other consumables to see how product pages are structured, or go straight to the procurement team. Request a formal quote for ZUMI devices by contacting Queenssurgical at queenssurgical.net — include your required SKU, quantity, and facility type, and a representative will respond with pricing and lead time within one business day.

 

Manufacturer and distributor sources for ZUMI verification

 

Before placing any order, procurement teams should pull directly from these authoritative sources to confirm current SKUs, IFU versions, and availability.

 

  • CooperSurgical Disposable Diagnostic Uterine Manipulators product page — primary source for SKUs, model descriptions, and IFU links

  • ZUMI Instructions for Use (IFU PDF) — required reading before first clinical use; contains indications, contraindications, insertion technique, and lot traceability requirements

  • McKesson catalog listing for ZSI1151 — distributor catalog reference for per-box pricing and availability

  • Artisan Medical ZUMI listing — additional US distributor catalog reference

 

Source

What It Provides

CooperSurgical product page

Authoritative SKU list, IFU link, material and sterility specs

ZUMI IFU PDF

Indications, contraindications, insertion technique, lot traceability

McKesson catalog

Per-box pricing, stock status, distributor ordering

Artisan Medical listing

Secondary US distributor reference for availability checks

Always use the manufacturer SKU (ZSI1151, ZSI1152, or ZSI1153) on purchase orders. A product name alone is not sufficient for a single-use sterile device order.

 

Recommended

 

 
 
 

Comments


bottom of page